Type 1 Spark Gap Surge Protector FLP25GR-275/2S

Main Features:

  • Location of Use: Main Distribution Boards

  • Network Systems: TN-S

  • Mode of Protection: L-PE, N-PE

  • Surge Ratings: Iimp = 25 kA (10/350 μs), In = 25 kA (8/20 μs)

  • IEC/EN Category: Class l+II / Type 1+2

  • Protective Elements: Spark Gap

  • Housing: Monobloc Design

  • Compliance: IEC 61643-11:2011, EN 61643-11:2012
  • Main Specification

    Type 1 Spark Gap Surge Protection FLP25GR-275/2S: Rated 230V, Uc 275V, Iimp 25kA (10/350μs), Up ≤1.5kV. For single-phase TN-S systems (L-PE, N-PE). DIN rail mount, IEC 61643-11 certified.

    Model No.FLP25GR-275/2S
    Nominal AC Voltage (50/60 Hz) Uo / Un230V
    Maximum Continuous Operating Voltage (AC) UC275V
    Nominal Discharge Current (8/20 μs) In25 kA
    Maximum Discharge Current (8/20 μs) Imax100 kA
    Impulse Discharge Current (10/350 μs) Iimp25 kA
    Specific Energy W/R156 kJ/Ω
    Charge Q12,5 As
    Voltage Protection Level Up1500 V
    Response Time tA< 25 ns
    Max. Backup Fuse315 A gL / gG
    Short-Circuit Current Rating (AC) ISCCR50 kA
    TOV Withstand 5 s UT335 V
    TOV 120 min UT440 V
    Number of Ports1

    Basic Circuit Diagram

    The Type 1 Spark Gap Surge Protector FLP25GR-275/2S is wired in a single-phase, 2-pole configuration (L-PE, N-PE) for TN-S systems, featuring integrated backup fuse protection.

    Dimensions

    The compact Type 1 Spark Gap Surge Protector FLP25GR-275/2S is designed for standard 35mm DIN rail mounting (EN 60715), ensuring easy integration into distribution boards.

    Installation Instructions

    For Type 1 Spark Gap Surge Protection FLP25GR-275/2S, mount on DIN rail, ensure correct wiring to L/N/PE, use proper torque on terminals, and connect remote signal contacts for status monitoring.

    Wiring Diagram & Installation

    Type 1 Spark Gap Surge Protector for TN-S systems, L-PE/N-PE protection. DIN rail mounting, wiring <50cm for optimal surge protection.

    Remote Signaling Terminal

    The Spark Gap Surge Protector features remote signaling terminals with NO/NC contacts for real-time remote monitoring of SPD status and fault alarms.

    Documentation

    Documentation for Type 1 Spark Gap Surge Protection FLP25GR-275/2S includes IEC/EN 61643-11 certificates, installation manual, and technical datasheet for single-phase TN-S system application. All documents available for download.

    Get A Quote Now

    Empower Sales and Maximize Market Potential with LSP